Pre-monsoon service window is open — condenser and drain work booked before 31 October.

Request a slot
Wild ParlorAircon Servicing Book a visit
Service technician in protective gloves working on an equipment control panel in a plant room

Split · Cassette · Window · Ducted fan coil

Cooling that is measured, cleaned and written up — not just switched on again.

Wild Parlor services air conditioning for homes, studios and small commercial floors. Every visit ends with a condition report: measured temperature split, drain condition, filter and coil state, and what the unit will need next.

  • Visiting hours
    Weekdays 08:00–18:00, Saturday mornings by arrangement
  • Units covered
    Wall split, ceiling cassette, window box, ducted fan coil
  • Report
    Written condition sheet emailed within one working day
  • Access
    Ladder work to 3.5m; sheets and floor protection carried as standard

Three kinds of visit

Pick the visit that matches what the unit is actually doing.

Most rooms need the annual service. Book the deep clean when airflow smells or the fins are matted; book a diagnosis when something has already failed. If you are unsure, describe it in the booking notes and we will tell you which one it is before we arrive.

01 / Annual service

Routine service

The maintenance visit that keeps a healthy unit healthy and catches drain and airflow problems while they are still cheap.

  • Full 14-point check on each indoor unit
  • Filters washed, dried and refitted
  • Drain line cleared and flow tested
  • Temperature split measured and logged
  • Outdoor coil rinsed and fan checked

About 45 min per unit · Once a year, twice for heavy use

02 / Deep clean

Chemical clean

For units that smell, drip, or blow weakly because the coil and blower wheel are loaded with biofilm and dust.

  • Indoor casing and blower wheel removed
  • Coil treated with a non-caustic cleaner
  • Drain pan lifted, flushed and sanitised
  • Blower wheel scrubbed vane by vane
  • Airflow re-measured before we sign off

About 2 hrs per unit · Every 2–3 years, sooner near cooking

03 / Fault work

Diagnosis & repair

When a unit trips, ices, leaks or refuses to start. We diagnose first and quote before any part is ordered.

  • Error code read from the board
  • Electrical draw and capacitor tested
  • Pressure and superheat checked on the line
  • Leak trace before any refrigerant is added
  • Written findings with repair or replace advice

About 1 hr to diagnose · Repair quoted separately

What a service actually includes

The 14-point service sheet

The same sheet is worked through on every routine visit, in this order, and every line is recorded on the report you receive.

  1. 01Room and supply air temperatures measured, split recorded
  2. 02Return air filters removed, washed and dried
  3. 03Evaporator coil inspected for matting and corrosion
  4. 04Blower wheel checked for dust loading and imbalance
  5. 05Drain pan cleared and condensate line flow tested
  6. 06Drain pump run and float switch confirmed working
  7. 07Indoor casing wiped, louvres freed and re-seated
  8. 08Mounting brackets and wall fixings checked for movement
  9. 09Pipe insulation inspected for gaps and sweating
  10. 10Outdoor coil rinsed clear of lint, leaves and grass
  11. 11Condenser fan blade, guard and bearing noise checked
  12. 12Contactor, terminals and capacitor visually inspected
  13. 13Running current compared against the unit rating plate
  14. 14Remote, timer and mode settings confirmed with you

If a step cannot be completed — a sealed ceiling void, a pump we cannot reach, a coil that needs the deep clean instead — it is marked on the sheet with the reason, not quietly skipped.

Gloved hands cleaning equipment with a cloth and spray bottle during a maintenance visit
Blower wheels and drain pans are cleaned by hand — the part of the job that decides whether a room smells in August.

Before you book

What the unit is doing, and what it usually means

Read the closest match. Some of these you can settle yourself in ten minutes, and we would rather you did than paid us to do it.

A It runs constantly but the room never gets cold

Usually airflow, not refrigerant. A loaded filter or a dust-packed blower wheel drops the volume of air across the coil, so the split between return and supply air collapses even though the compressor is working hard.

Try first: pull the filters and hold them to the light. If you cannot see through them, wash them, dry them fully and run the unit again for an hour. If unchanged: book a deep clean so the coil and wheel are dealt with properly.

B Water drips from the indoor unit

Almost always a blocked condensate path. The pan fills faster than it drains, then overflows at the lowest corner of the casing. On cassettes it is often the pump float sticking instead.

Try first: switch the unit off and let the pan empty, and check the outside drain outlet is not capped by debris or a nest. Then: book a service — the drain is cleared and flow tested as standard.

C There is ice on the pipework or the coil

Icing means the coil is running colder than it should, which points to restricted airflow or low refrigerant charge — and low charge means a leak somewhere, because these are sealed systems.

Do this: turn cooling off and run fan-only to defrost before anything is inspected. Then: book fault work. We leak trace before adding gas; topping up a leaking system is money poured into the garden.

D A sour or musty smell for the first few minutes

Biofilm on the evaporator and in the drain pan. It grows in the damp left behind after each run, and it is strongest at start-up when the first air pushes through it.

Worth knowing: filter washing alone will not shift it, and spray fresheners only mask it. A chemical clean removes the growth at the source; running the fan for ten minutes after cooling helps keep it from returning.

E The unit trips the breaker or will not start

Electrical. A tired start capacitor, pitted contactor, seized fan motor or a compressor drawing well above its rating will all present the same way at the consumer unit.

Please do not: keep resetting the breaker — a unit that trips repeatedly is telling you something is drawing current it should not. Book: fault work, and mention the error code on the display if one is shown.

Planning the year

When to do what

Air conditioning fails in the first hot week because nothing was done in the quiet months. This is the rhythm we work to with regular clients.

PeriodDo thisWhy it matters
Late winter Book the annual service while diaries are open Slots are wide, and any part that needs ordering arrives long before you need the unit
Spring Clear the condenser surround — plants, bags, stored boxes An outdoor unit that cannot breathe runs hot and shortens its own compressor life
Early summer Run each unit for an hour and note anything odd Finding a fault in June is a booking; finding it in August is a wait
Peak season Wash filters monthly, keep doors and windows shut while cooling Filters load fastest in constant use, and open doors make the unit chase a room it cannot win
Autumn Deep clean if there was any smell or drip during the season Cleaning before the unit sits idle stops growth settling in over winter
Year-round Run fan-only for ten minutes after heavy cooling Drying the coil is the single cheapest thing you can do for air quality
Bright, calm living room with pale walls and soft daylight, comfortably cooled
A serviced unit holds a set temperature quietly instead of cycling hard against a room it cannot hold.

Request a visit

Tell us the units and the access

Those two things decide the length of the visit and what we bring. We reply with a proposed window and a written scope before anything is confirmed.

  • Step oneWe read your notes and confirm which visit type fits.
  • Step twoYou get a time window, the expected duration and the scope in writing.
  • Step threeWe arrive with sheets, a ladder and the filters most units need.
  • Step fourThe condition report is emailed within one working day.
No obligation. We confirm scope and a time window by email before any work is booked in.

Questions we get every week

Practical answers, before you ask

How often does a unit really need servicing?

Once a year for normal household use. Twice a year if the unit runs most days, sits in a kitchen, faces a busy road, or serves a room with pets. Window units in dusty locations sit closer to the twice-a-year end.

Do you top up refrigerant as part of a service?

No, and nobody should. A correctly installed system does not consume refrigerant. If the charge is low there is a leak, so we trace and repair it first — otherwise you are paying to fill a system that will empty again.

What do you need from me on the day?

Clear floor beneath each indoor unit, access to the outdoor unit, somewhere to draw water for filter washing, and the remote. If the unit is above a stairwell or in a sealed void, tell us in the notes so we bring the right access kit.

Can you service a unit you did not install?

Yes — most of what we look after was installed by someone else. If we find an installation fault, such as a drain run falling the wrong way or missing pipe insulation, it goes on the report with what it would take to correct.

The unit is noisy rather than broken. Is that a service job?

Often yes. Rattles are usually loose louvres, a slack casing screw or a bracket that has shifted, and all three are covered by the routine visit. A deeper grinding or whining noise is a bearing or fan issue and is better booked as fault work.

I am a tenant — can I book, or does the landlord?

You can book, and many tenants do, but confirm who is paying before we arrive. For handovers we can address the report to the managing agent as well as to you, so the unit's condition is documented at the change of tenancy.

Will a clean actually make the room colder?

If airflow was the limit, yes, and the measured split on the report will show it. If the unit is undersized for the room or the glazing is unshaded, cleaning will not fix that, and we will say so rather than sell you a second visit.

What do you not do?

We do not carry out new installations, ductwork design or electrical work beyond the unit's own isolator and terminals. Where a job needs any of those, the report says exactly what is required so another trade can quote from it.